  • The HR500D is a self-contained unit with integral extract and supply fans to provide balanced ventilation and heat recovery via supply diffusers and extraction grilles.
Quantity:
  • Usually Despatches Within 2 Working Days
Dispatched & sold by: i-sells
facebook

Description

Product Description

    • The compact heat recovery cube interleaves outgoing warm air with incoming fresh air and allows the heat from one to warm the other without the two streams mixing
    • Filter: Should be a washable reticulated foam type coarse filter
    • Installation HR500D is designed for installation in external walls and should be fitted to provide a 3° slope to outside to provide condensate drainage
    • Energy is saved on room heating with no power being used by the cube itself
    • Spigots are provided for 315, 250 and 200mm Ø ducting accessories to internal extract and supply grilles
    • It shall operate up to an ambient temperature of 40°C and be fitted with a manual reset thermal overload protective device.The supply motor shall be configured to be reversible thus providing an extract only option
    • Ideal for offices, computer rooms, pubs and clubs, etc
    • Performance of HR500D: Supply and extract up to 174 l/s FID capacity on heat recovery mode
    • The unit is fully speed controllable
    • Typical Range Specifications Performance: m³/h l/s Max ventilation rate 625 173 Efficiency: The unit should retain up to 70% of the temperature differential of out going air
    • Complies to the following approvals/directives: LVD, EMC & CE
    • Range Performance Airflow Performance l/s (max) Watts (max) dB(A) @ 3m (max) Flush Box Stock Ref No 174 210 53 40 01 44 Range DimensionsFitting Hole Size: 610mm × 381mm Weight: 19kg Power Consumption Supply fan 60.0W Extract fan 150.0W
    • Fan: The 2-N° polymeric fan impellers should be of a mixed flow type, dynamically balanced mounted on a fixed stator housing
    • Construction: The unit outer case should be a rigid HIPs moulding configured so as to make the unit telescopic
    • Sound Levels: Report upon request Mains electrical supply: 230VAC 50Hz
    • Heat exchanger: Should be of a multi plate cross-flow type constructed out of a polymeric plastic with ultra sonic welded joints
    • Motor: Should be a 240V 50Hz A/C with sleeve bearings, greased for life
    • Ducting spigots: The unit should provide 315, 250 and 200mm Ø spigots for both duct connections.The unit cannot be handed
    • The internal/external grille should be a cream coloured ABS moulding